20GP Air-Cooled Mining Container — 144 Machines at 66 kW

20GP Air-Cooled Mining Container — 144 Machines at 66 kW

Categories:

144 machines at 66 kW in a 20 ft box — the size you buy when the feed is 380 V and the shipping budget matters.

144machines
66 kWdesign load
10fans
2per 40HQ
01 / OVERVIEW

What it is for

The 20 ft box exists for two reasons: a 380 V feed that cannot carry a 40 ft load, and a shipping budget that is counted in containers rather than in megawatts. Two of them fit in a 40HQ with the doors on, which changes the freight arithmetic completely.

At 66 kW it is not a compromise on quality — it is the same shell construction, the same per-position breakers and the same negative-pressure airflow, in half the length and half the machine count.

Where it is typically used

Small sites300 kW or less, where a 40 ft box would sit half empty.
380 V suppliesWhere the available feed will not carry a 1,200 A main.
Islands and remote campsTwo units per 40HQ keeps the freight per megawatt down.
Pilot deploymentsProve the site with 66 kW before committing to a farm.
02 / SPECIFICATIONS

Key specifications

Shell 20GP, CSC plated, 6,058 × 2,438 × 2,591 mm
Machines 144 at 3.5 kW class, 4 columns × 36
Design load 66 kW at 35 °C ambient
Power 1 cabinet, 1,250 A main, 12 × 100 A + 1 × 80 A branch
PDU 12 strips, switchable per socket
Airflow 10 × 1,000 mm negative-pressure fans
Inlet Water curtain + 40-mesh filter, snow baffle optional
Network 6 × 24-port switches, one cable per machine
Weight About 11 t loaded
Build time 25–35 days from drawing release

Figures are for the standard configuration and change with the project. Values are design values; acceptance follows the contract technical agreement.

03 / WHAT IS INSIDE

What goes in the box

Installed, wired and tested before dispatch. On site the work is placement and external connections.

01Certified shell

20GP with CSC plate, insulated roof, one service door and one escape door.

02Power cabinet

Single cabinet, main breaker and branch protection per position.

03PDU strips

Twelve strips, reachable from the aisle without a ladder.

04Air path

Ten fans, filtered inlet, aisle separation panels.

05Network and spares

Switches and cabling, plus the same spares kit as the 40 ft.

04 / MODELS

Which model to take

Model Machines Load Feed Per 40HQ
MC-AIR-20-S 144 66 kW 380 V 50 Hz 2 units
MC-AIR-20-H 132 60 kW 380 V 50 Hz 2 units
MC-AIR-20-C 144 66 kW 415 V 60 Hz 2 units

Standard models are listed. Other capacities are built to order, with two to three weeks added to the standard lead time.

05 / TECHNICAL NOTES

Two per 40HQ is the number that decides this box

ENGINEERING NOTE

Freight, not steel, is the variable

A 20GP and a 40HC cost nearly the same to move on most lanes. Two 20 ft boxes therefore carry 288 machines for one 40 ft freight bill, against 336 machines for the same bill — so the 40 ft still wins on paper, and the 20 ft wins whenever the destination cannot take a 40 ft trailer or a 12 m turning circle.

That last constraint is more common than people expect: mountain roads, island ferries, and sites where the gate is 8 m wide.

Freight is quoted per container, so the 20 ft box wins on cost per megawatt on long routes even though the 40 ft wins on cost per kilowatt installed.

06 / SELECTION

When to use it, when not to

These come from projects rather than general advice. Match your case against them; it is more useful than reading the specification table.

The site cannot physically take a 40 ft container.

This is the honest reason to buy it, and it is the most common one.

Your feed is 380 V and limited.

A 20 ft box stays inside what the transformer will give you.

You need the lowest cost per installed kilowatt.

The 40 ft is cheaper per kW. Buy it unless something stops you.

You want to run hydro machines.

Water cooling in a 20 ft shell exists, but at 0.55 MW the economics are tighter.

07 / DELIVERY

From contract to energisation

Drawing

Machine model, feed voltage, transport route. Four days.

Production

25–35 days from drawing release.

Test

Rated load test with the ambient logged.

Ship

Two per 40HQ, braced, spares kit inside one of them.

08 / GALLERY

On site and in detail

A 20 ft air-cooled container on a paved site
A 20 ft air-cooled container on a paved site
Machine rows in a 20 ft frame
Machine rows in a 20 ft frame
Loading for export
Loading for export
Louvred wall and inlet panels
Louvred wall and inlet panels

Some images are scheme illustrations and renders showing structure and layout. Final delivery follows the contract drawings.

09 / FAQ

What customers ask most

Can two units share one substation?

Yes, and it is the normal arrangement: one 250 kVA unit for two boxes with spare ways.

Is the 20 ft box quieter than the 40 ft?

Slightly, because there are fewer fans, but it is the same order of noise. Plan for 66–70 dB(A) at ten metres.

Can it be stacked?

Two high on corner castings, if the pad and the access allow. We supply the stacking kit and the brace drawing.

What is the lead time on a repeat order?

20–25 days, because the drawings and the electrical build are already fixed.

Ask for a scheme for your site

Send the capacity, rack count, site conditions and local climate. You get a layout, a single-line diagram and a price, at no charge, revised until it works.

See the mining range

Product Details

Half the box, the same discipline

144 machines at 3,520 W per position, 66 kW in total, on a 1,250 A main with 12 × 100 A and one
80 A branch. The 20 ft shell costs less to move, fits where a 40 ft will not, and still gets one breaker
per machine rather than a shared rail.

Where a 20GP wins

Small sites with a 380 V feed, yards where the crane is small, and deployments where the boxes travel
by road more often than by sea. Two 20GP units also give you a way to grow: run one, keep the second cold
until the machines arrive.

Key figures

  • 144 machines · 66 kW · 3,520 W per position · 20GP shell
  • 1,250 A main · 12 × 100 A + 1 × 80 A branch protection
  • Negative-pressure fan wall with 40-mesh inlet filtration
  • PDU strips switchable per socket · labelled cable schedule on handover
  • Ships as a standard container — CSC plate retained

Built to order. Same airflow and power logic as the 40HC, scaled to the box.

gallery
RELATED PRODUCT
Clean agent fire suppression cylinders inside a container
Detection & Suppression — Clean Agent for Mining Containers
A containerised transformer and switchgear skid outdoors
Mining Substation & Paralleling Skid — 1.25 to 2.5 MVA
A 20-foot water-cooled mining container on a paved site
20GP Water-Cooled Mining Container — 96 Hydro Units at 0.55 MW
Water-cooled mining containers in a row along a street
Water-Cooled Mining Farm — 2 to 10 MW with a Shared Heat Rejection Loop
Contact us