A 40 ft expandable office at 77 m²: fourteen desks, a glazed meeting room, a manager’s office and a server corner with its own circuit and extract.

77 m²office floor
14–16desks
3rooms
1per 40HQ
01 / OVERVIEW

What it is for

An office for sixteen people needs three things a container office usually does not have: a meeting room that is not the corner of the open plan, a wall long enough for a screen, and enough cooling that the afternoon does not end at two o’clock.

The 40 ft double-wing gives all three. 77 m² is a fourteen-desk open plan plus a glazed meeting room plus a manager’s office, and the fixed core takes the server cabinet, the WC and the kitchenette without eating the desks.

The WCO4021 is that unit. It is what a project office becomes when the project runs for three years and the client stops thinking of it as temporary.

Where it is typically used

Project and site headquartersFourteen desks, a meeting room, a manager’s office and a server corner.
Sales and marketing suitesA reception, a model table, two meeting rooms and a WC.
Temporary school and training roomsTwo classrooms and an office, with the partition on the drawing.
Remote and field officesA full office where there is no building and no intention of building one.
02 / SPECIFICATIONS

Key specifications

Folded size 12,000 × 2,228 × 2,504 mm
Open size 12,000 × 6,454 × 2,504 mm
Floor area 77 m² / 829 ft² clear span
Desks 14–16 open plan, or 10 with two meeting rooms
Rooms Meeting room (glazed), manager’s office, server corner
Structure Galvanised frame, two folding wings, aluminium wall frame
Walls 75 mm PU panel for a permanent office; 50 mm for a short cycle
Glazing Double-glazed fixed elevation, 12 m, with 4 opening lights and an external blind option
Electrical RCBO board, 24 twin sockets, 20 data points, 6 AC circuits, UPS option
Cooling 2 × 5 kW split or a 4-zone cassette system, sized from a load schedule
Loading 1 unit per 40HQ
Options WC pod, kitchenette, UPS, server rack, solar-ready DC, external deck

Figures are for the standard configuration and change with the project. Values are design values; acceptance follows the contract technical agreement.

03 / WHAT IS INSIDE

What goes in the box

Installed, wired and tested before dispatch. On site the work is placement and external connections.

01Open plan

A 12 m clear span with no columns, so the desk layout can change without cutting steel.

02Meeting room

A glazed aluminium stud partition with an acoustic door, positioned on the drawing.

03Services wall

Power, data and the board in skirting trunking on the fixed wall, never in a folding panel.

04Server corner

A ventilated cabinet position with a dedicated circuit and its own extract, in the fixed core.

05Kitchenette and WC

In the fixed core, on the one stack, so no service crosses a hinge line.

06Roof void

AC lines, data and the extraction for the server run in the roof, above the ceiling.

04 / MODELS

Which model to take

Model Open area Desks Rooms Best for
WCO4021-OP 77 m² 16 Open plan + 1 meeting Project offices
WCO4021-2M 77 m² 10 2 meeting + manager Client-facing suites
WCO4021-WC 77 m² 12 Meeting + WC + kitchenette Standalone offices
WCO4021-SR 77 m² 12 Meeting + server room Sites with local IT

Standard models are listed. Other capacities are built to order, with two to three weeks added to the standard lead time.

05 / TECHNICAL NOTES

The two failures of a container office

ENGINEERING NOTE

A 12 m glazed elevation is a heating load

Twelve metres of glass facing west will put 8 kW of solar gain into a 77 m² room on a summer afternoon. No split unit fixes that; the glass has to be dealt with first.

So the glazing is low-e with a 6 mm inner pane, and we price an external blind as part of the base specification rather than as an option. Tell us which way the frontage faces before we size the air conditioning, because the answer changes by a factor of two.

Sixteen desks is not one circuit

Sixteen laptops, thirty-two monitors, a printer, a server, a kettle, a microwave and two air conditioners. That is a distribution board with labelled circuits, not a 16 A supply with a daisy chain.

We split lighting, sockets, AC and the kitchenette onto separate circuits, put a UPS option on the server circuit, and laminate the load schedule inside the door. The person who resets the board at 9 a.m. is never the person who ordered the building.

Heat and power. Nobody ever complains about the floor area of a 77 m² office.

06 / SELECTION

When to use it, when not to

These come from projects rather than general advice. Match your case against them; it is more useful than reading the specification table.

You need 14 or more desks.

77 m² is the smallest expandable that does it without a compromise.

You need a real meeting room.

A glazed partition with an acoustic door, on the drawing.

There is a server or a network cabinet.

Dedicated circuit, extract and UPS option in the fixed core.

Eight desks is enough.

The 20 ft office is cheaper and ships two per container.

You are staying for twenty years.

At that point a fixed building wins on cost per year, and we will say so.

07 / DELIVERY

From contract to the first opening

Brief

Headcount, room requirement, IT load, summer temperature, frontage orientation. Layout in 48 hours.

Drawing

Desk plan, partitions, electrical and data layout, AC positions and the pad drawing, signed before production.

Production

36 days for the shell; 45 with partitions, AC, WC and kitchenette.

Test

Circuit test and tag, data continuity, AC commissioning record, water test on both roof joints.

Packing

Folded, partitions crated flat, AC units and the server cabinet boxed and labelled by room.

Handover

Two days: open, connect, commission, hand over the drawings and walk the client through the board.

08 / GALLERY

On site and in detail

A 40 ft double-wing office opened on grass, white cladding and 12 m of glazing
A 40 ft double-wing office opened on grass, white cladding and 12 m of glazing
Open plan after opening, desks along the glazed elevation
Open plan after opening, desks along the glazed elevation
Meeting room behind a glazed partition at the end of the unit
Meeting room behind a glazed partition at the end of the unit

Some images are scheme illustrations and renders showing structure and layout. Final delivery follows the contract drawings.

09 / FAQ

What customers ask most

Can it hold 16 people comfortably?

Fourteen comfortably, sixteen if two of them are hot-desking. The limit is not floor area, it is the single entrance and the meeting room, and both are on the drawing so you can see it before you order.

How much cooling does it need?

Between 8 and 12 kW in a hot climate with an unshaded west frontage, and about 5 kW in northern Europe. We size it from a load schedule and we will tell you if the answer is a blind rather than a second unit.

Is the meeting room acoustic?

Rw 38 with mineral wool and a double seal, plus a solid-core door with a drop seal. It is a working meeting room, not a recording studio, and we will say which one you are getting.

Can two units be joined?

Yes, end to end with a joining kit and a roof cover, giving a 24 m office. Side by side needs a beam over a 6.5 m span, which we price separately.

What happens to it at the end of the project?

It folds, ships and opens again. That is the point: a 40 ft expandable is an asset that moves to the next project, not a building you write off.

Ask for a layout for your site

Send the site, the headcount, the ground conditions and the climate. You get a floor plan, a fold sequence and a price, at no charge, revised until it works.

See the full expandable range

Product Details
gallery
RELATED PRODUCT
Card Exp Exp40S
WCS4011 — 40 ft Expandable Container House, Single Wing
Card Exp Exp30
WCE3011 — 30 ft Expandable Container House, 58 m²
Trailer-mounted expandable unit on a street (catalogue crop)
WCT2011 — Trailer-Mounted Expandable Unit on a Road Chassis
Double-wide expandable cafe with canopy (catalogue crop)
WCB4021 — 40 ft Expandable Café, Bar and Retail Unit
Contact us

Committed to providing customers with high-quality and reliable container solutions.