WCO2011 — 20 ft Expandable Container Office

WCO2011 — 20 ft Expandable Container Office

A 20 ft expandable office at 37 m²: eight to ten desks, a partition, split circuits for printer and AC, two units per 40HQ and four hours to a working office.

37 m²open plan when open
8–10desks, two rooms
2,228 mmfolded for freight
4 hto a working office
01 / OVERVIEW

What it is for

A site office is usually the first building on a site and the last one anybody thinks about. It is also the one that has to work in a heatwave, hold a printer, a server cabinet and eight people, and be gone in a morning when the project ends.

A 20 ft fixed container gives 13.9 m², which is three desks and an argument. The expandable gives 37 m², which is eight desks, a meeting table and a wall for the drawings — and it still ships two to a container.

The WCO2011 is that office with the electrical and data specification already decided, because a site office fails on power and cooling far more often than on floor area.

Where it is typically used

Project and site officesEight desks, a meeting table and a drawing wall, with a partition for the manager.
Sales and letting suitesA desk at the glass, a model table and a WC pod at the rear.
Temporary classrooms and training roomsOne room, one door, one supply — the simplest compliant space on a site.
Clinics and welfare officesA reception, a consulting room and a waiting area, with the pod plumbed in the factory.
02 / SPECIFICATIONS

Key specifications

Folded size 5,900 × 2,228 × 2,504 mm
Open size 5,900 × 6,454 × 2,504 mm
Floor area 37 m² / 398 ft² clear span
Desks 8–10 depending on the partition; 6 with a meeting room
Structure Galvanised frame, folding roof and floor panels, aluminium wall frame
Walls 50 mm PU panel; 75 mm when the unit is a permanent office
Glazing Double-glazed on the fixed elevation, 2 opening lights
Electrical RCBO board, 12 twin sockets, 8 data points, 4 × LED panel, 1 × 16 A circuit for AC
Cooling 2 × 3.5 kW split, or a single 5 kW cassette for the open plan
Loading 2 units per 40HQ
Options Partition, WC pod, server cabinet, UPS, solar-ready DC circuit, step ramp

Figures are for the standard configuration and change with the project. Values are design values; acceptance follows the contract technical agreement.

03 / WHAT IS INSIDE

What goes in the box

Installed, wired and tested before dispatch. On site the work is placement and external connections.

01Open plan

A clear span with no columns, so the desks can be rearranged without cutting anything.

02Services wall

Power, data and the board on one wall, in skirting trunking, so nothing is chased into a folding panel.

03Glazed elevation

The fixed 5.9 m side is glazed; the folding walls are solid so there is somewhere to hang a screen.

04Floor

Cement board with a 2 mm commercial vinyl and a sealed centre joint under a trim cover.

05Partition

An aluminium stud partition, glazed or solid, positioned on the drawing and not on site.

06Roof

50 mm insulated panel with a service void for the AC lines and the data drops.

04 / MODELS

Which model to take

Model Open area Desks Rooms Best for
WCO2011-OP 37 m² 8–10 Open plan Site and project offices
WCO2011-1P 37 m² 6 + 2 Office + manager Supervision with a meeting room
WCO2011-WC 37 m² 6 + 2 Office + WC pod Standalone units with no site facilities
WCO2011-SR 37 m² 6 Office + server Sites with a local network cabinet

Standard models are listed. Other capacities are built to order, with two to three weeks added to the standard lead time.

05 / TECHNICAL NOTES

Power and cooling decide whether it works

ENGINEERING NOTE

One 16 A supply is not an office supply

Eight desks is eight laptops, two monitors each, a printer, a kettle, a microwave and an air conditioner. That is not a 16 A circuit, and the reason site offices get a reputation for tripping is that they are wired like a cabin.

We split it: a lighting and socket ring, a dedicated AC circuit, and a separate 16 A circuit for the kettle and the printer. The board is labelled inside the door and the drawing is laminated and screwed to the wall, because the person who resets it is never the person who ordered it.

Cooling is a load calculation, not a product

A 37 m² office with a glazed 6 m elevation and no shading needs about 5 kW in a Gulf summer and about 2.5 kW in northern Europe. Specifying one 3.5 kW split for both is how a unit gets a reputation for being hot.

Tell us the summer design temperature and which way the glass faces. We will size the unit and, if the glass is unshaded and west-facing, we will tell you to add the external blind before you add the second air conditioner.

A site office is not judged on its floor. It is judged on whether the printer trips the board in August.

06 / SELECTION

When to use it, when not to

These come from projects rather than general advice. Match your case against them; it is more useful than reading the specification table.

You need more than three desks.

37 m² is the smallest expandable that behaves like an office.

There is a printer, a server or a kettle.

The circuits are split for it in the factory.

The unit will be on site for more than a year.

75 mm walls and a proper AC spec are worth the difference.

You need two separate rooms and a corridor.

Go to the 40 ft office; a 20 ft partition gives one small room.

The site is in a cyclone zone at full exposure.

Tell us first — the glazing and anchoring change, and we will price it.

07 / DELIVERY

From contract to the first opening

Brief

Headcount, equipment list, summer temperature, which way the glass faces. Layout in 48 hours.

Drawing

Desk plan, electrical layout, AC positions and the foundation pad, signed before production.

Production

25 days for the shell; 30 with the partition, AC and WC pod.

Test

Circuit test and tag, AC commissioning record, water test on the roof joint and the floor seam.

Packing

Folded, with the partition and the AC units crated separately and labelled by room.

Handover

One day: open, connect, commission, and walk the client through the board.

08 / GALLERY

On site and in detail

A 20 ft expandable office opened beside a garden, timber-look frontage and glazed elevation
A 20 ft expandable office opened beside a garden, timber-look frontage and glazed elevation
Interior: desk run along the glazed wall, meeting table at the blind end
Interior: desk run along the glazed wall, meeting table at the blind end
The same unit from the side, showing the solid folding wall used for storage
The same unit from the side, showing the solid folding wall used for storage

Some images are scheme illustrations and renders showing structure and layout. Final delivery follows the contract drawings.

09 / FAQ

What customers ask most

Can it hold a server cabinet?

Yes, in the corner on the services wall, with a dedicated circuit and a small extract fan. A full rack needs a split of its own; tell us the heat load and we will size it rather than guess.

Is the partition structural?

No. It is an aluminium stud partition and it can be moved later, provided you keep the fixing points off the purlin line. We mark them on the drawing.

What is the floor loading?

300 kg/m² uniformly, which is a normal office. A compactus or a heavy safe needs a spreader plate and a note on the drawing.

How many units fit in a container?

Two 20 ft expandables per 40HQ. That is the number that makes the product work on a long route — a fixed 20 ft office ships one per container for a third of the floor.

Can it be used as a permanent office?

Yes, with 75 mm walls, a pitched roof over the top and a proper foundation. At that point compare it with a fixed building: the expandable wins on speed and loses on life expectancy.

Ask for a layout for your site

Send the site, the headcount, the ground conditions and the climate. You get a floor plan, a fold sequence and a price, at no charge, revised until it works.

See the full expandable range

Product Details

An office that fits through the gate

Folded, the unit is narrow enough to pass a site gate and light enough for a small crane. Open, it is a
37 m² office with a glazed front, a meeting end and a services wall. The transition is a morning’s work,
not a construction programme.

Where it is used

Project offices on sites that will be gone in two years. Sales suites where the glazing has to face the
street. Site canteens and welfare rooms that have to meet a standard without a permanent building.

Key figures

  • 37 m² open footprint · glazed front
  • Folded thickness 2,228 mm · several units per container
  • Insulated panels, pre-run wiring and lighting
  • Partition options for a second room or a WC pod
  • Stacking frame available for two storeys

Built to order. The glazing run and the partition layout are the variables.

gallery
RELATED PRODUCT
Card Exp Exp40S
WCS4011 — 40 ft Expandable Container House, Single Wing
Folded expandable container house with timber cladding (catalogue crop)
WCF2011 — Foldable Expandable Container House, Flat-Pack Panels
20 ft expandable container shop with orange awnings open onto a street
WCB2011 — 20 ft Expandable Container Shop and Retail Unit
Trailer-mounted expandable unit on a street (catalogue crop)
WCT2011 — Trailer-Mounted Expandable Unit on a Road Chassis
Contact us

Committed to providing customers with high-quality and reliable container solutions.