Generator & Switchgear Container — Sound-Attenuated Diesel and Gas Sets

Generator & Switchgear Container — Sound-Attenuated Diesel and Gas Sets

Categories:

Sound-attenuated generator containers at 65–75 dB(A) at one metre, with the radiator air path calculated and the switchgear in the same box.

20–40 ftshell
65–75dB(A) at 1 m
2,000 Lday tank max
C4corrosion
01 / OVERVIEW

What it is for

A generator in a container has two problems to solve at once: the radiator has to move enough air to keep the set cool, and the box has to be quiet enough for the site it stands on. Those two requirements fight each other, and the box that loses is the one built by cutting a hole and bolting on a grille.

We build the airflow path first — intake louvre, turning vanes, radiator duct, discharge — and then line the box to hit the noise figure, because attenuation added afterwards always costs more than attenuation designed in.

The electrical room goes at the other end: switchgear, protection relays, a metering panel and a cable entry with spare ways. Factory-wired and tested, so on site the work is the fuel connection, the exhaust and the cable termination.

Where it is typically used

Prime powerRemote sites, mines and camps where the grid is not coming.
Standby for critical loadsData centres, hospitals and cold stores that cannot wait for a utility.
Construction phase powerA set that moves with the project and leaves with it.
Hybrid with renewablesGenset plus PV and storage, where the set runs fewer hours and the enclosure must still pass noise.
02 / SPECIFICATIONS

Key specifications

Shell 20 ft or 40 ft HC, CSC plate, new-build frame on request
Set range 200–1,500 kVA diesel; gas sets on request
Acoustic rating 65–75 dB(A) at 1 m, 55–65 dB(A) at 10 m depending on lining
Air path Intake louvre with filters, radiator duct, discharge plenum, all sized to the fan curve
Day tank 500–2,000 L integral, bunded, with level gauge and low-level alarm
Exhaust Critical silencer inside the box, stainless flex, wall penetration with thermal sleeve
Switchgear LV panel with main breaker, ATS or manual changeover, metering and protection
Ventilation Thermostatic fans or louvres, interlocked to the set run signal
Fire Detection and clean agent on request; fuel shut-off interlock as standard
Corrosion C4 three-coat epoxy standard, C5-M for coastal
Noise doors Acoustic doors with double seals and a service door at each end
Design ambient −20 °C to +50 °C, derating stated for altitude above 1,000 m

Figures are for the standard configuration and change with the project. Values are design values; acceptance follows the contract technical agreement.

03 / WHAT IS INSIDE

What goes in the box

Installed, wired and tested before dispatch. On site the work is placement and external connections.

01Acoustic shell

Container or new-build frame lined with mineral wool and perforated sheet, sealed at every joint.

02Air path

Louvres, filters, radiator duct and discharge plenum, calculated against the set fan curve.

03Fuel system

Bunded day tank, fill point with spill containment, level gauge and low-level alarm.

04Exhaust

Critical or residential silencer, stainless flex section, insulated penetration.

05Electrical room

Switchgear, ATS, metering, protection and a cable entry with spare ways.

06Controls

Set controller, remote start terminals, alarm contacts to the site system.

04 / MODELS

Which model to take

Model Shell Set size Noise Fuel
EQ-GEN-20 20 ft · 6,058 × 2,438 200–500 kVA 65–70 dB(A) @ 1 m 500–1,000 L
EQ-GEN-40 40 ft · 12,192 × 2,438 500–1,250 kVA 70–75 dB(A) @ 1 m 1,000–2,000 L
EQ-GEN-40S 40 ft · split rooms 500–1,250 kVA 65–70 dB(A) @ 1 m 1,000–2,000 L
EQ-GEN-GAS 40 ft · gas 200–800 kWe 70–75 dB(A) @ 1 m Gas train, no day tank

Standard models are listed. Other capacities are built to order, with two to three weeks added to the standard lead time.

05 / TECHNICAL NOTES

The radiator decides the louvre area, and the louvre decides the noise

ENGINEERING NOTE

Free area, not louvre size

A louvre quoted at 1 m² gives you roughly 0.5 m² of free area once the blades are in it. Radiator airflow is quoted in m³/s against a pressure drop, and if the free area is too small the set derates or overheats — quietly, and only on the hottest day.

We calculate the free area from the set fan curve and add the filter and duct losses, then check that the louvre size still fits the acoustic target. If it does not, the box gets a taller discharge plenum rather than a hole.

Attenuation is a lining decision, not a door decision

The difference between 75 and 65 dB(A) at one metre is usually 50 mm more mineral wool, a sealed double door and a ducted discharge — decided at design, priced into the shell.

Acoustic kits bolted on afterwards cost more, look like kits, and rarely hit the number the site permit asked for.

Airflow and acoustic calculations are issued with the drawing. If a customer changes the set after drawing release, both are recalculated rather than patched on site.

06 / SELECTION

When to use it, when not to

These come from projects rather than general advice. Match your case against them; it is more useful than reading the specification table.

You have the set model, the kVA and the site noise limit.

Those three numbers size the box.

The enclosure must pass a permit condition.

We can quote to a dB(A) figure at a stated distance and test it before dispatch.

You want the switchgear in the same box.

One delivery, one interface, one set of drawings.

You need 2 MW or more.

That is a power station, not a container — a different structural and ventilation problem.

The set is going indoors in a plant room.

Then you need acoustic treatment and ducting, not a container.

07 / DELIVERY

From contract to energisation

Data

Set make and model, kVA, fan curve, noise limit, fuel volume, voltage.

Drawing

General arrangement, airflow calculation and acoustic prediction in 5–7 days.

Contract

Drawing release, deposit, set ordered if we are sourcing it.

Production

35–50 days: shell, lining, air path, fuel tank, electrical, factory run test.

Handover

Load test at the site rating, noise measurement, as-built drawing and O&M file.

08 / GALLERY

On site and in detail

A sound-attenuated generator container with louvred ventilation
A sound-attenuated generator container with louvred ventilation
Container end showing louvre bank and access door
Container end showing louvre bank and access door
Louvred panels and cooling intake on an equipment container
Louvred panels and cooling intake on an equipment container
Equipment containers installed outdoors at a customer site
Equipment containers installed outdoors at a customer site

Some images are scheme illustrations and renders showing structure and layout. Final delivery follows the contract drawings.

09 / FAQ

What customers ask most

Do you supply the generator set?

We can, as a named make with a model number so you can price it independently. Many customers supply their own set and we build the room around it.

How quiet can you make it?

65 dB(A) at one metre is achievable on a 40 ft box with a split-room layout. Below that you are looking at a residential-grade enclosure, which is a different product.

What about the exhaust?

Critical silencer inside the box, stainless flex and an insulated wall penetration. The stack height above the roof is a site decision and we will draw it.

Can it run on gas?

Yes, on a 40 ft shell with a gas train instead of a day tank. Ventilation and detection change with the fuel, so the drawing is not the diesel one.

Does the tank need bunding?

Yes, and it is integral. Fill point, spill containment and a low-level alarm are standard, because a fuel spill is an environmental incident, not a maintenance item.

Ask for a scheme for your site

Send the capacity, rack count, site conditions and local climate. You get a layout, a single-line diagram and a price, at no charge, revised until it works.

See the enclosure range

Product Details

Noise, heat and rain, handled by the same shell

A genset in the open is a maintenance item. In a container it is a machine with a roof over it:
louvred intake and discharge sized to the radiator, an exhaust penetration with a weather hood, a bundled
fuel area and doors wide enough to pull the alternator without cutting steel.

Where it is used

Construction sites that cannot run a cable, telecom towers on standby, and industrial yards where the
utility feed is not to be trusted. Because it is a container, it moves when the project moves.

Key figures

  • 20 ft and 40 ft · louvre area sized to the radiator airflow
  • Exhaust penetration with weather hood and insulation
  • Bunded fuel zone · fire-rated separating wall to switchgear
  • Doors and removable panels for alternator access
  • CSC shell · lifting points marked

Built to order. Send the genset datasheet — airflow, exhaust position and
footprint decide the layout.

gallery
RELATED PRODUCT
Card Eq Haz
Hazardous Waste & Chemical Store — Bunded, Ventilated, Signage That Passes Inspection
Card Eq Hvac V2
Enclosure HVAC & Ventilation — Cooling, Explosion-Proof Fans, Motorised Louvres
Card Eq Pump
Pump & Compressor House — Heavy Floor, Acoustic Lining, Real Ventilation
Card Eq Lab V2
Mobile Laboratory Container — Fume Extraction, Bench and a Sink That Drains
Contact us

Committed to providing customers with high-quality and reliable container solutions.