A 384 kWh storage and generator cabinet standing outdoors on a paved yard

Project case · Energy storage · Cabinet system

384 kWh in one cabinet, on a slab, running the same week

A park operator needed peak shaving and standby power without a switchroom. The answer was a single outdoor cabinet with the battery, the converter and the controls already inside it.

384 kWhusable capacity per cabinet
IP54outdoor enclosure
Grid / off-gridboth modes supported
One slabno switchroom required
ClientIndustrial park operator (confidential)
LocationSouthern China
ScopeOutdoor storage and generator cabinet, integrated
ContractSupply, integration, commissioning support
DutyPeak shaving and standby, remote monitored
01 / The brief

A battery room that does not need a room

What the site could not build

A conventional battery installation wants a room: walls, a door, fire separation, cooling, and a cable route back to the switchboard. On an operating site there is usually no room to put that room, and no appetite for the construction programme it implies.

The load here was modest and the peaks were predictable. What the operator needed was capacity it could set down on an existing slab, connect and run, with the possibility of moving it when the site layout changes.

What we supplied

One cabinet, with the battery modules, the power conversion system, the distribution and the controller inside. Thermal management and fire suppression are part of the cabinet, not part of the building, and the whole unit is rated for outdoor duty at IP54.

Commissioning is a cable connection and a settings check. The unit runs grid-tied for peak shaving and transfers to standby when the supply drops; both modes are exercised before handover, and the operator sees the state of charge and the alarms remotely.

02 / What we delivered

What is inside the cabinet and why it matters

Outdoor rated, not sheltered
01 / EnvelopeOutdoor rated, not sheltered

IP54 shell with a sealed cable entry and a rain hood over the louvres. A cabinet that assumes a canopy is a cabinet that fails in the first monsoon.

Cooling sized to the duty cycle
02 / ThermalCooling sized to the duty cycle

Thermal management sized for continuous peak-shaving cycles, not for occasional discharge. Battery life is a thermal question before it is a chemistry one.

Detection inside the cabinet
03 / SafetyDetection inside the cabinet

Smoke and temperature detection with a suppression arrangement inside the enclosure, and a shutdown that does not depend on the site network.

03 / Sequence

From slab to first cycle

Step 1SizingLoad profile and peak window reviewed against cabinet capacity.
Step 2IntegrationBattery, PCS, distribution and controls assembled and tested.
Step 3DeliveryCabinet shipped complete, lifted onto the prepared slab.
Step 4ConnectionPower and communications terminated, protection settings applied.
Step 5HandoverCharge and discharge cycles run, both modes demonstrated.
04 / By the numbers

The numbers the operator works to

384 kWhusable capacity in one cabinet
IP54outdoor enclosure rating
Two modesgrid-tied and standby
Remotestate of charge and alarms

Values describe the configuration as delivered. Commercial terms are not disclosed.

05 / Site record

The cabinet, and the systems around it

Sister project: a 40 ft storage cabin lifted inside the assembly hall
Sister project: a 40 ft storage cabin lifted inside the assembly hall
Sister build: cabinets staged on the apron, access ladders in place
Sister build: cabinets staged on the apron, access ladders in place
Sister project: cabinets set against a building elevation
Sister project: cabinets set against a building elevation
A shell of the same family leaving the paint shop
A shell of the same family leaving the paint shop
Figures & disclosure

Published as an anonymised reference. The client is not named and the site location is given only to region level. Commercial values (contract sum, unit price) are withheld; the technical figures describe the configuration as delivered. Where a number has been rounded or scaled for confidentiality it is stated in the note above.

Send the load profile and the slab dimensions.

Tell us the peak window, the standby requirement and where the cabinet will stand. We will come back with the capacity, the connection arrangement and the protection settings.

Talk to an engineer

Contact us