384 kWh in one cabinet, on a slab, running the same week
A park operator needed peak shaving and standby power without a switchroom. The answer was a single outdoor cabinet with the battery, the converter and the controls already inside it.
A battery room that does not need a room
What the site could not build
A conventional battery installation wants a room: walls, a door, fire separation, cooling, and a cable route back to the switchboard. On an operating site there is usually no room to put that room, and no appetite for the construction programme it implies.
The load here was modest and the peaks were predictable. What the operator needed was capacity it could set down on an existing slab, connect and run, with the possibility of moving it when the site layout changes.
What we supplied
One cabinet, with the battery modules, the power conversion system, the distribution and the controller inside. Thermal management and fire suppression are part of the cabinet, not part of the building, and the whole unit is rated for outdoor duty at IP54.
Commissioning is a cable connection and a settings check. The unit runs grid-tied for peak shaving and transfers to standby when the supply drops; both modes are exercised before handover, and the operator sees the state of charge and the alarms remotely.
What is inside the cabinet and why it matters

IP54 shell with a sealed cable entry and a rain hood over the louvres. A cabinet that assumes a canopy is a cabinet that fails in the first monsoon.

Thermal management sized for continuous peak-shaving cycles, not for occasional discharge. Battery life is a thermal question before it is a chemistry one.

Smoke and temperature detection with a suppression arrangement inside the enclosure, and a shutdown that does not depend on the site network.
From slab to first cycle
The numbers the operator works to
Values describe the configuration as delivered. Commercial terms are not disclosed.
The cabinet, and the systems around it




The products this specification maps to
Published as an anonymised reference. The client is not named and the site location is given only to region level. Commercial values (contract sum, unit price) are withheld; the technical figures describe the configuration as delivered. Where a number has been rounded or scaled for confidentiality it is stated in the note above.
Send the load profile and the slab dimensions.
Tell us the peak window, the standby requirement and where the cabinet will stand. We will come back with the capacity, the connection arrangement and the protection settings.