A white equipment enclosure built for an electronics manufacturer, standing outdoors

Project case · Special custom · Electronics

A box built around one machine: heat, shielding and vibration

An electronics manufacturer needed its test equipment housed outside the production hall, with the heat path, the shielding and the mounting all resolved around one specific machine.

One machinethe envelope is built around it
Shieldedseams and penetrations bonded
Vibrationisolated at the mounting
Power ontested before dispatch
ClientElectronics technology company (confidential)
LocationSouthern China
ScopeCustom equipment enclosure with dedicated thermal and shielding design
ContractDesign, fabrication, equipment pre-installation, power-on test
RequirementDimensional fit, heat rejection, EMC and vibration isolation
01 / The brief

A standard box would have failed on three counts

Why it could not be a generic enclosure

The machine had a footprint, a cable exit height and a service clearance that no catalogue enclosure matches. It also rejected heat in a narrow band, which meant the air path had to be designed around the machine rather than around the room.

The third constraint was electrical. The equipment is sensitive enough that seam bonding and penetration treatment stop being details and become the reason the enclosure works.

What we built

An envelope dimensioned to the machine, with a dedicated supply and return air path, filtered intake and a thermal set sized to the measured heat load rather than a rule of thumb. Panels are bonded at the seams and every penetration is treated, including the cable entry and the door seal.

The machine was installed and powered at the factory, with the enclosure around it. That turns the site work into a delivery: the unit arrives as a working assembly, not as a container and a separate commissioning exercise.

02 / What we delivered

The three design decisions that carry the project

Dimensioned to the machine
01 / FitDimensioned to the machine

Footprint, cable exit height and service clearance taken from the equipment drawing. Clearance to the walls is a maintenance requirement, not spare space.

A path, not a unit
02 / HeatA path, not a unit

Supply and return arranged so air crosses the machine. Adding a bigger air conditioner to a badly arranged room does not fix a heat problem.

Seams and penetrations bonded
03 / ShieldingSeams and penetrations bonded

Panel joints bonded, cable entries treated, door seal continuous. Shielding is decided at the details, not by the panel gauge.

03 / Sequence

From equipment drawing to power-on

Step 1SurveyMachine drawing, heat load and cable routes recorded.
Step 2EnvelopeShell dimensioned around the equipment and the service clearance.
Step 3Pre-installMachine set, isolated and connected inside the enclosure.
Step 4Power-onThermal and functional test with the equipment running.
Step 5DeliveryUnit shipped as a working assembly, ready for site connection.
04 / By the numbers

What the enclosure was designed against

One machineenvelope dimensioned to its drawing
Measuredheat load, not a rule of thumb
Bondedseams, entries and door seal
Isolatedmounting against structure-borne vibration

Values describe the configuration as delivered. Equipment details and commercial terms are not disclosed.

05 / Site record

The build, and the systems inside it

Sister build: a sealed enclosure with insulated doors and a wall-mounted unit
Sister build: a sealed enclosure with insulated doors and a wall-mounted unit
Interior of a walk-in enclosure, lined and lit
Interior of a walk-in enclosure, lined and lit
Clean-panel interior with a sealed floor and coved joints
Clean-panel interior with a sealed floor and coved joints
Sister build: a clean-panel shell of the same build system leaving the factory
Sister build: a clean-panel shell of the same build system leaving the factory
Figures & disclosure

Published as an anonymised reference. The client is not named and the site location is given only to region level. Commercial values (contract sum, unit price) are withheld; the technical figures describe the configuration as delivered. Where a number has been rounded or scaled for confidentiality it is stated in the note above.

Send the machine drawing and the heat load.

Tell us the footprint, the cable exit and the environment it has to sit in. We will come back with the envelope, the air path and the shielding details.

Talk to an engineer

Contact us