A test cell for battery packs, built with the fire case first
A battery manufacturer needed a test enclosure on a production site: exhaust for a thermal event, temperature control for the test, and a structure sized for the load it carries.
The test is designed to fail, so the room has to be
What a battery test cell has to survive
A test cell runs packs to their limits on purpose. The enclosure therefore has to be designed for the event, not for normal operation: an extract path that removes smoke and gas, a suppression arrangement that does not depend on the site, and a structure that does not distort when the equipment is loaded onto it.
The test itself also needs a controlled environment. Temperature affects the result, so a cell that drifts with the weather produces data that cannot be compared between runs.
What we built
An enclosure with a reinforced floor sized to the test rig, dedicated smoke and gas extraction, fire detection and suppression, and a thermal system holding the test temperature within a band.
Detection, extraction and suppression were tested at the factory as a sequence, which is the part that is hardest to prove once the unit is on a production site.
Three systems that define the cell

Dedicated extraction with the intake and discharge positioned for a thermal event, not for general ventilation. The two are different systems.

Reinforced floor and frame sized to the rig, with the load path taken to the base frame rather than to the panels.

Temperature and humidity controlled to a band so results compare between runs. Weather is not a variable a test cell can tolerate.
From test specification to first run
What the cell is designed for
Values describe the configuration as delivered. Test capacity and commercial terms are not disclosed.
The cell, and the systems behind it




The products this specification maps to
Published as an anonymised reference. The client is not named and the site location is given only to region level. Commercial values (contract sum, unit price) are withheld; the technical figures describe the configuration as delivered. Where a number has been rounded or scaled for confidentiality it is stated in the note above.
Send the test profile and the rig drawing.
Tell us what the cell has to contain, how the rig is loaded and where the extract can discharge. We will come back with the enclosure and the system sequence.