A battery test enclosure being lifted complete outside the factory

Project case · Energy storage · Battery testing

A test cell for battery packs, built with the fire case first

A battery manufacturer needed a test enclosure on a production site: exhaust for a thermal event, temperature control for the test, and a structure sized for the load it carries.

Test cellpurpose-built enclosure
Extractsmoke and gas, dedicated
Thermalheld to the test profile
Reinforcedfloor for the equipment load
ClientBattery manufacturer (confidential)
LocationChina
ScopeBattery test enclosure with fire, exhaust and thermal provisions
ContractDesign, build, systems integration, factory test, delivery
RequirementsExplosion protection, smoke extraction, thermal control, structural capacity
01 / The brief

The test is designed to fail, so the room has to be

What a battery test cell has to survive

A test cell runs packs to their limits on purpose. The enclosure therefore has to be designed for the event, not for normal operation: an extract path that removes smoke and gas, a suppression arrangement that does not depend on the site, and a structure that does not distort when the equipment is loaded onto it.

The test itself also needs a controlled environment. Temperature affects the result, so a cell that drifts with the weather produces data that cannot be compared between runs.

What we built

An enclosure with a reinforced floor sized to the test rig, dedicated smoke and gas extraction, fire detection and suppression, and a thermal system holding the test temperature within a band.

Detection, extraction and suppression were tested at the factory as a sequence, which is the part that is hardest to prove once the unit is on a production site.

02 / What we delivered

Three systems that define the cell

Smoke out, before it spreads
01 / ExtractSmoke out, before it spreads

Dedicated extraction with the intake and discharge positioned for a thermal event, not for general ventilation. The two are different systems.

A floor that does not move
02 / StructureA floor that does not move

Reinforced floor and frame sized to the rig, with the load path taken to the base frame rather than to the panels.

Held to the test profile
03 / ThermalHeld to the test profile

Temperature and humidity controlled to a band so results compare between runs. Weather is not a variable a test cell can tolerate.

03 / Sequence

From test specification to first run

Step 1SpecificationTest profile, rig dimensions and event case agreed.
Step 2EnvelopeStructure, floor and extract path designed around the rig.
Step 3SystemsDetection, extraction, suppression and thermal installed.
Step 4Factory testSystems proven as a sequence before dispatch.
Step 5HandoverUnit set, services connected, first run witnessed.
04 / By the numbers

What the cell is designed for

Dedicatedsmoke and gas extraction
Reinforcedfloor and frame for the rig load
Controlledtemperature and humidity band
Sequenceddetection, extraction and suppression proven together

Values describe the configuration as delivered. Test capacity and commercial terms are not disclosed.

05 / Site record

The cell, and the systems behind it

Sister build: a 40 ft storage cabin lifted inside the assembly hall
Sister build: a 40 ft storage cabin lifted inside the assembly hall
Sister build: a completed storage cabin on the test apron
Sister build: a completed storage cabin on the test apron
Access side open: converter, distribution and controller
Access side open: converter, distribution and controller
Sister build: equipment cabins staged on site before handover
Sister build: equipment cabins staged on site before handover
Figures & disclosure

Published as an anonymised reference. The client is not named and the site location is given only to region level. Commercial values (contract sum, unit price) are withheld; the technical figures describe the configuration as delivered. Where a number has been rounded or scaled for confidentiality it is stated in the note above.

Send the test profile and the rig drawing.

Tell us what the cell has to contain, how the rig is loaded and where the extract can discharge. We will come back with the enclosure and the system sequence.

Talk to an engineer

Contact us