A box built around one machine: heat, shielding and vibration
An electronics manufacturer needed its test equipment housed outside the production hall, with the heat path, the shielding and the mounting all resolved around one specific machine.
A standard box would have failed on three counts
Why it could not be a generic enclosure
The machine had a footprint, a cable exit height and a service clearance that no catalogue enclosure matches. It also rejected heat in a narrow band, which meant the air path had to be designed around the machine rather than around the room.
The third constraint was electrical. The equipment is sensitive enough that seam bonding and penetration treatment stop being details and become the reason the enclosure works.
What we built
An envelope dimensioned to the machine, with a dedicated supply and return air path, filtered intake and a thermal set sized to the measured heat load rather than a rule of thumb. Panels are bonded at the seams and every penetration is treated, including the cable entry and the door seal.
The machine was installed and powered at the factory, with the enclosure around it. That turns the site work into a delivery: the unit arrives as a working assembly, not as a container and a separate commissioning exercise.
The three design decisions that carry the project

Footprint, cable exit height and service clearance taken from the equipment drawing. Clearance to the walls is a maintenance requirement, not spare space.

Supply and return arranged so air crosses the machine. Adding a bigger air conditioner to a badly arranged room does not fix a heat problem.

Panel joints bonded, cable entries treated, door seal continuous. Shielding is decided at the details, not by the panel gauge.
From equipment drawing to power-on
What the enclosure was designed against
Values describe the configuration as delivered. Equipment details and commercial terms are not disclosed.
The build, and the systems inside it




The products this specification maps to
Published as an anonymised reference. The client is not named and the site location is given only to region level. Commercial values (contract sum, unit price) are withheld; the technical figures describe the configuration as delivered. Where a number has been rounded or scaled for confidentiality it is stated in the note above.
Send the machine drawing and the heat load.
Tell us the footprint, the cable exit and the environment it has to sit in. We will come back with the envelope, the air path and the shielding details.