A containerised chiller station with louvred access doors, standing outdoors

Project case · Data centre · Cooling plant

A chilled water plant in a box, next to the hall it cools

A data hall needed a dedicated chilled water plant with no plant room to put it in. The magnetic-bearing chillers, pumps, pipework, distribution and controls arrived as one commissioned station.

One stationchillers, pumps, pipework, controls
Magneticbearing chillers, part-load efficient
Acoustictreated enclosure
Factorycommissioned before delivery
ClientData centre operator (confidential)
LocationSouthern China
ScopeContainerised water-cooled magnetic-bearing chiller station
ContractDesign, integration, factory commissioning, delivery
ConsiderationsAcoustics, vibration isolation, precise temperature control
01 / The brief

Cooling is the part of a data centre that arrives last

What the hall needed

The hall itself was straightforward. The problem was the plant: a chilled water system with magnetic-bearing machines, pumps, headers and controls, normally built into a plant room that the building programme has to deliver first.

On this site there was no plant room and no time to build one. The station also had to sit close to the hall, which turned acoustics and structure-borne vibration from a footnote into a design constraint.

What we built

A containerised station with the chillers, primary pumps, headers, distribution and the control system inside. Pipework is fabricated to the module, pressure-tested, and the whole plant is run at the factory against a load bank before it ships.

The enclosure is acoustically treated and the rotating plant is isolated at the base, so the station can stand beside an occupied building. On site it is a lift, a water connection and a power connection.

02 / What we delivered

Three constraints that shaped the station

Treated, because it stands close
01 / AcousticsTreated, because it stands close

Acoustic lining and sealed doors so the station can sit next to the hall it serves. Distance is not available on a dense site.

Isolated at the base
02 / VibrationIsolated at the base

Rotating plant on isolation mounts, pipework on flexible connections. Structure-borne noise travels further than airborne noise and is harder to fix later.

Commissioned as a plant
03 / ControlCommissioned as a plant

Sequencing, setpoints and alarms proven against a load bank at the factory, so the site test confirms rather than discovers.

03 / Sequence

From load calculation to first chilled water

Step 1DutyCooling load and part-load profile reviewed against machine selection.
Step 2IntegrationChillers, pumps, headers and controls installed in the module.
Step 3Pressure testPipework tested and flushed before the plant is run.
Step 4Load bankStation commissioned at the factory across its operating range.
Step 5SiteStation set, water and power connected, performance verified.
04 / By the numbers

What the station is specified to hold

One stationchillers, pumps, headers and controls
Magneticbearing machines, efficient at part load
Treatedacoustic enclosure and isolated base
Factorycommissioned against a load bank

Values describe the configuration as delivered. Cooling capacity and commercial terms are not disclosed.

05 / Site record

The station, inside and out

The station envelope: a containerised water-cooled chiller plant on its base
The station envelope: a containerised water-cooled chiller plant on its base
Lined interior with a sealed floor and coved joints
Lined interior with a sealed floor and coved joints
Louvred access face, sealed against weather
Louvred access face, sealed against weather
Sister build: a skid-mounted package with access platform
Sister build: a skid-mounted package with access platform
Figures & disclosure

Published as an anonymised reference. The client is not named and the site location is given only to region level. Commercial values (contract sum, unit price) are withheld; the technical figures describe the configuration as delivered. Where a number has been rounded or scaled for confidentiality it is stated in the note above.

Send the cooling load and the part-load profile.

Tell us the supply and return temperatures, the space available and the noise limit at the boundary. We will come back with the station arrangement and the commissioning scope.

Talk to an engineer

Contact us

Committed to providing customers with high-quality and reliable container solutions.

ACTBOXES Whatsapp